Humidity Generator and Dry Air Supply Unit

DY-SLD80 Dew point meter calibration system

2020-12-6 本文被阅读 13 次

图片1.png

DY-GZ Dry Air Supply Unit

◇ 产品简介 ◇ 产品功能◇ 技术指标◇ 订购信息◇ 资料下载◇ 相关产品

[Product Introduction]

DY-SLD80,The dew point generator in this system realizes dew point adjustment based on the principle of shunt method. Gases with different dew point temperatures can be obtained through different ratios of dry and wet air flows. This method can use multi-stage split matching according to actual needs to generate the desired dew point value gas source. Our company provides a super dryer that can reduce the dew point to below -60°C (-80°C) and provide a drying air source, so the dew point value can be adjusted arbitrarily between -60°C (-80°C) and 20°C. , and can achieve fully automatic and rapid control.

[Technical Indicator]

图片2.png

1. Technical parameters of precision dew point meter:

1.1 Dew point range: -80℃ to +20℃dp

1.2 Accuracy: ±0.2℃ dew point; ±0.1℃ temperature

1.3 Mirror surface: gold-plated copper

1.4 Repeatability: 0.05℃

1.5 Contamination compensation system: Automatic optical path balance system DCC

1.6 Temperature probe: 4-wire Pt100,1/10 DIN class B

1.7 Pressure range: 1Mpa

1.8 Sample gas flow: 0~2.4L/min

1.9 Display: flow rate, dew point temperature measurement and display

1.10 Output: Serial communication R232

1.11 Refrigeration method: semiconductor + Stirling dual refrigeration, no additional refrigeration module required

2. Technical parameters:

2.1. Technical indicators meet JJG826-93 "Secondary Standard Shunt Humidity Generator"; meet JJF1272-2011 Resistance-Capacitance Method Dew Point Hygrometer Calibration Specifications

2.2. Principle of humidification: Principle of split flow method

2.3. Power supply: AC 220V/50Hz

2.4. Working environment temperature: +5℃~+40℃

2.5. Working environment humidity: 10%RH~85%RH

2.6. Dry gas generator

Minimum frost point/dew point: -85°C(dp)

Output flow: 0...10L/min

2.7. Humidity generator 

Occurrence range: -80℃~+10℃ (dp)

Fluctuation: < ±0.1°C (dp) within 30 minutes

Accuracy: < ±0.1°C (dp)

Output flow: 0~3L/min each channel

Display: true color touch LCD screen

Operation: Multiple presets are available, and the operation process is simple

Air connection: 1/4’ stainless steel ferrule connector

Output flow adjustment: high-precision stainless steel flow adjustment valve

Saturator water level: front panel scale indication




图片3.png


DY-SLD80 Dew point meter calibration system
  • Online message

  • Your name
    You must fill in your title
  • TEL
    Must fill in mobile phone number
  • Email
    Required
  • Company
    Optional
  • Whatsapp/Skype
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what do you want to consult?
  • Verification code: Please fill in the calculation result.
上一条:DY-XJY02 Temperature and Humidity Field Test System/Temperature and Humidity Inspection Instrument下一条:DY-HT3F-D Split portable high temperature short cavity blackbody furnace

Taian Demei Electromechanical Equipment Co.,LTD.

Chinese